0 changing components – Baxi Potterton Condensing Combination Boiler Performa 24 Eco HE User Manual

Page 37

Advertising
background image

14.0

Changing Components

37

© Baxi Heating UK Ltd 2009

IMPORTANT: When changing components ensure
that both the gas and electrical supplies to the
boiler are isolated before any work is started.
When the new component has been fitted turn the
selector switch fully anticlockwise against the spring
pressure to the ‘Reset’ position and hold for 2
seconds to reset the boiler before recommissioning.

See Section 13.1 “Annual Servicing” for removal of case
panel, door etc.

14.1

Fan (Figs. 62 & 63)

1. Note the positions of the sensing tube on the outlet
elbow and three wires on the fan motor and remove
them.

2. Slacken the screw on the fan spigot outlet pipe clamp.
Ease the clamp to the left over the pipe.

3. Remove the four screws securing the combustion box
door and remove the door.

4. Ease the front edge of the left hand baffle upwards,
disengaging the spring clip. Disengage the tab on the
baffle from the slot in the fan hood.

5. Undo the screws securing the fan hood to the
appliance back panel, and draw the fan and hood
assembly forwards.

6. Remove the screws and spring washers securing the
fan to the hood, and the screw securing the outlet pipe.

7. Transfer the outlet pipe and clamp to the new fan.

8. Fit the new fan to the hood using the screws and
spring washers previously removed.

9. Reassemble in reverse order of dismantling.

14.2

Pressure Switch (Fig. 61)

1. Remove the fan and hood assembly as described in
section 14.1.

2. Note the positions of the two sensing tubes and
wires and remove them.

3. Remove the two screws holding the pressure switch
to the bracket on the combustion box top panel.

4. Fit the new pressure switch and reassemble all
components in reverse order of dismantling.

Fan Hood

Spring Washer

Securing Screw

Pressure
Switch

Sensing
Tubes

Pressure

Switch Wires

Fig. 61

Fan Wires

Fan

Sensing

Tube

Ease Outlet Pipe Clamp

To The Left

Fig. 62

Fan Spigot

Outlet Pipe

Spring Clip

Baffle

Tab

Fan

Fig. 63

Advertising