14.0

Changing Components

46

© Baxi Heating UK Ltd 2009

14.23

Secondary Heat Exchanger (Fig. 87)

1. Drain the primary circuit

2. Undo the four screws securing the right hand case

panel. Remove the panel.

3. Prise the connecting clips from the heat exchanger

return pipe and the boiler return pipe. Remove the

pipes.

4. Remove the fan and hood assembly as described in

Section 14.1

5. Remove the nut securing the elbow to the secondary

heat exchanger. Draw the elbow and outlet pipe

forwards.

6. Remove the secondary heat exchanger from the

outer drum by easing it forward.

7. Reassemble in reverse order of dismantling.

14.24

Flue Overheat Thermostat (Fig. 88)

NOTE: The flue overheat thermostat includes a

reset button. Check that the thermostat will not

reset before replacing.

1. Remove the fan and hood assembly as described in

Section 14.1

2. Pull the two wires off the terminals on the flue

overheat thermostat. Unscrew the thermostat from the

adaptor in the outlet elbow.

3. Reassemble in reverse order of dismantling.

Overheat Thermostat

Secondary
Heat Exchanger

Outer Drum

Boiler Return Pipe

Pipe Connecting Clip

Elbow

Heat Exchanger
Return Pipe

Fig. 87

Fig. 88