0 fault finding – Baxi Potterton Condensing Combination Boiler Performa 24 Eco HE User Manual

Page 49

Advertising
background image

49

© Baxi Heating UK Ltd 2009

16.0

Fault Finding

Domestic Hot Water - Follow operational sequence

Turn selector to

neon illuminated

Primary flow switch operated

Fan runs at max speed

Pump runs

Turn thermostat to max.
Open DHW tap fully. DHW

flow switch operated

Primary water is diverted

from CH system to DHW

heat exchanger and flow

microswitch operated

Continuity across DHW flow

microswitch terminals and

PCB - M1 connector

terminals 13 & 14 (terminals

12-14 open)

Air pressure switch proved

neon illuminated

Burner on neon

illuminated

Spark at ignition electrodes

for up to 10 seconds

Go to section ‘A’

Go to section ‘B’

Go to section ‘C’

Go to section ‘J’, ‘L’ & ‘D’

Replace PCB

Turn the selector to the reset

position. If the light does not

extinguish go to section

H & K

Go to section ‘F’

Go to section ‘I’

DHW flow valve

senses no flow.

Primary water diverted to

CH system. DHW flow

switch released off

Close DHW tap

Burner goes out

Diverter valve spindle

assembly faulty

Pump stops

Operation sequence correct

Turn the selector switch to

the ‘Reset’ position and hold

for at least 2 seconds. If

regular resetting is required,

or appliance still does not

operate investigation is

necessary

Go to section ‘E’

Burner extinguishes

after 10 seconds

YES

YES

YES

YES

YES

YES

YES

YES

YES

YES

YES

YES

YES

YES

YES

YES

NO

Fan stops

NO

YES

YES

YES

NO

NO

DHW flow rate more than

2.5l/min.

Is mains water

filter and differential

assembly clean?

DHW flow valve diaphragm

damaged

DHW flow valve rod

obstructed

Replace DHW flow

microswitch

Replace PCB

Replace diaphragm

NO

NO

NO

YES

NO

NO

NO

NO

NO

NO

NO

NO

Reduce the DHW flow rate.

If burner does not modulate

clean temperature sensor and

DHW heat exchanger. If

modulation does not occur

go to section ‘G’

Burner output modulates to

maintain temperature set at

thermostat

NO

Advertising