background image

4-22 System Configuration

The table below lists how selections for "AC LINK" determine the power status of the server when
the power supply to the server restarts.

Parameter

State before powered off

Stay Off

Last State

Power On

In

service

Off On On

Out of service (DC power: Off)

Off

Off

On

Forced

shutdown

*

Off Off On

* Pressing the POWER switch for over four seconds shuts down the power to the server.

Thermal Sensor

Select "Thermal Sensor" on the System Hardware menu and press Enter to display the following
screen.

Phoenix BIOS Setup Utility

Thermal Sensor:

Upper Limit:
Lower Limit:

Determines if BIOS will
disable boot, if the
temperature is not
within safe range.

Item Specific Help

Thermal S

ensor

[Enabled]

[48]
[5]

System Hardware

elp

t

Sub-Menu

F10 Save Changes & Exit

F9 Setup Defaults

-/+ C ange Values

h

Enter Select

Select Item

enu

Select M

F1 H

xi

Esc E

See the table below for setup options on the screen.

Option Parameter

Description

Your

Setting

Thermal
Sensor

[Enabled]
Disabled

Enable or disable the thermal sensor
monitoring feature.

Upper Limit

7 - [48] - 80

Specify the upper limit temperature for
boot-up restriction in Celsius. Use + and/or -
keys to specify a value by adding a number
greater than 7 to the value specified for
Lower Limit.

Lower Limit

0 - [5] - 73

Specify the lower limit temperature for
boot-up restriction in Celsius. Do not specify
4 degrees or lower. Use + and/or - keys to
specify a value by deducting a number
greater than 7 to the value specified for
Upper Limit.

[ ]: Factory-set