background image

Troubleshooting 7-21

Linux Error Messages

NEC Express5800/ft series displays messages on the console window when failures occur. Also, the
same information is recorded as system logs.

The following indicates the syslog messages, messages on the console, their meanings and actions:

Message Meaning

Action

FT[dev.no] opstate SIMPLEX to DUPLEX

The status changed
from SIMPLEX to
DUPLEX

FT[dev.no] opstate ONLINE to DUPLEX

The status changed
from ONLINE to
DUPLEX

FT[dev.no] opstate INITIALIZING to DUPLEX

The status changed
from INITIALIZING to
DUPLEX

FT[dev.no] opstate BROKEN to DUPLEX

The status changed
from BROKEN to
DUPLEX

FT[dev.no] opstate INITIALIZING to
DIAGNOSTICS

The status changed
from INITIALIZING to
DIAGNOSTICS

FT[dev.no] opstate INITIALIZING to ONLINE

The status changed
from INITIALIZING to
ONLINE

FT[dev.no] opstate ONLINE to INITIALIZING

The status changed
from ONLINE to
INITIALIZING

FT[dev.no] opstate DIAGNOSTICS to
DIAGNOSTICS_PASSED

Diagnostics have
completed

FT[dev.no] opstate UNKNOWN to INITIALIZING

The status changed
from UNKNOWN to
INITIALIZING

The server is
operating
normally.

FT[dev.no] opstate SIMPLEX to BROKEN

The status changed
from SIMPLEX to
BROKEN

FT[dev.no] opstate UNKNOWN to EMPTY

The status changed
from UNKNOWN to
EMPTY

Contact your
sales agent.

FT[dev.no] opstate INITIALIZING to BROKEN

Failed to start the
device

Start the server
again. If the
problem persists,
contact your sales
agent.

FT[dev.no] operation BRINGUP failed

Failed to start the
device.

Start the server
again. If the
problem persists,
contact your sales
agent.