7-18 Troubleshooting

On-screen error message

Cause

Action

0BD6 3rd SMBus device

address not
acknowledged

0BD7 3rd SMBus device Error

detected

0BD8 3rd SMBus timeout

-

(3rd SMBus does not exist)

0BD9 4th SMBus device

address not
acknowledged

0BDA 4th SMBus device Error

Detected

0BDB 4th SMBus device

timeout

CPU module board #2 is faulty.

0BDC 5th SMBus device

address not
acknowledged

0BDD 5th SMBus device Error

detected

0BDE 5th SMBus timeout

-

(5th SMBus does not exist)

0BDF 6th SMBus device

address not
acknowledged

0BE0 6th SMBus device Error

detected

0BE1 6th SMBus timeout

-

(6th SMBus does not exist)

0BE2 7th SMBus device

address not
acknowledged

0BE3 7th SMBus device Error

detected

0BE4 7th SMBus timeout

Back panel board is faulty.

0BE5 8th SMBus device

address not
acknowledged

0BE6 8th SMBus device Error

detected

0BE7 8th SMBus timeout

PCI module board #2 is faulty.

Check cable connection.

Replace the board.

0BF0 Vendor ID cannot be

retrieved from BP
IDPROM

0BF1 System Structure cannot

be retrieved from BP
IDPROM

Back panel board is faulty.

Replace the back panel board.

0C00 Rompilot reports error

number xx

Configuration error in
SETUP.

CPU/PCI module board is
faulty.

Re-configure Rompilot.

Replace the CPU/PCI
module board.

8600 No working DQS value

found

DIMM is faulty

DIMM is not supported

Replace DIMM

Replace DIMM with
appropriate one.