7-10 Troubleshooting

STATUS LED

Indication

Color

State

Suspected

module

Explanation Procedure

CPU00 Temp Alm
00

Amber Blink CPU module #1 CPU#1 temperature alarm

(lower limit)

CPU00 Temp Alm
02

Amber

Lit

CPU module #1 CPU#1fatal temperature alarm

(lower limit)

CPU00 Temp Alm
07

Amber Blink CPU module #1 CPU#1temperature alarm

(upper limit)

CPU00 Temp Alm
09

Amber

Lit

CPU module #1 CPU#1 fatal temperature

alarm (upper limit)

CPU01 Temp Alm
00

Amber Blink CPU module #2 CPU#2 temperature alarm

(lower limit)

CPU01 Temp Alm
02

Amber

Lit

CPU module #2 CPU#2 fatal temperature

alarm (lower limit)

CPU01 Temp Alm
07

Amber Blink CPU module #2 CPU#2 temperature alarm

(upper limit)

CPU01 Temp Alm
09

Amber

Lit

CPU module #2 CPU#2 fatal temperature

alarm (upper limit)

Check to see if dust is
accumulated on the
internal fans. Check also
if the fan cables are
connected securely. If
not solved by the above,
contact your sales agent.

CPU2 +12ss Alm
00

Amber

Blink CPU module #2 12-V power voltage alarm

(lower limit)

CPU2 +12ss Alm
02

Amber

Lit

CPU module #2 Fatal 12-V power voltage

alarm (lower limit)

CPU2 +12ss Alm
07

Amber Blink CPU module #2 12-V power voltage alarm

(upper limit)

CPU2 +12ss Alm
09

Amber

Lit

CPU module #2 Fatal 12-V power voltage

alarm (upper limit)

CPU2 +12v Alm
00

Amber Blink CPU module #2 12-V power voltage alarm

(lower limit)

CPU2 +12v Alm
02

Amber

Lit

CPU module #2 Fatal 12-V power voltage

alarm (lower limit)

CPU2 +12v Alm
07

Amber Blink CPU module #2 12-V power voltage alarm

(upper limit)

CPU2 +12v Alm
09

Amber

Lit

CPU module #2 Fatal 12-V power voltage

alarm (upper limit)

CPU2 +1.5vAlm
00

Amber Blink CPU module #2 1.5-V power voltage alarm

(lower limit)

CPU2 +1.5vAlm
02

Amber

Lit

CPU module #2 Fatal 1.5-V power voltage

alarm (lower limit)

CPU2 +1.5vAlm
07

Amber Blink CPU module #2 1.5-V power voltage alarm

(upper limit)

CPU2 +1.5vAlm
09

Amber

Lit

CPU module #2 Fatal 1.5-V power voltage

alarm (upper limit)

Contact your sales
agent.

CPU2 +2.5vAlm
00

Amber Blink CPU module #2 2.5-V power voltage alarm

(lower limit)

CPU2 +2.5vAlm
02

Amber

Lit

CPU module #2 Fatal 2.5-V power voltage

alarm (lower limit)

CPU2 +2.5vAlm
07

Amber Blink CPU module #2 2.5-V power voltage alarm

(upper limit)

CPU2 +2.5vAlm
09

Amber

Lit

CPU module #2 Fatal 2.5-V power voltage

alarm (upper limit)

Contact your sales
agent.