7-16 Troubleshooting

On-screen error message

Cause

Action

0B29 Unsupported Processor

detected on Processor 2

The processor (CPU) not
supported by this server is
installed in Processor 2.

Install the CPU appropriate to
the server.

0B30 CPU FAN #1 Alarm

occurred

0B31 CPU FAN #2 Alarm

occurred

Dusts are clogged in fan.

Fan is faulty.

CPU module board is faulty.

Replace the fan.

Replace the CPU module
board.

Connect fan cable properly.

0B32 CPU FAN #3 Alarm

occurred

Dusts are clogged in fan.

Fan is faulty.

CPU module board is faulty.

Replace the fan.

Replace the CPU module
board.

Connect fan cable properly.

0B40 Invalid System

Configuration Data

Configuration error in
SETUP.

CPU/PCI module board is
faulty.

Reset the setting by
selecting [Yes] at [Reset
Configuration Data]

Replace the CPU/PCI
module board.

0B41 System Configuration

Data Read error

Configuration error in
SETUP.

CPU/PCI module board is
faulty.

Reset the setting by
selecting [Yes] at [Reset
Configuration Data]

Replace the CPU/PCI
module board.

0B42 Resource Conflict

Configuration error in SETUP.

Correct device configuration in
SETUP

0B43 Warning: IRQ not

configured

Configuration error in SETUP.

Correct settings in SETUP

0B44 Expansion Rom not

initialized

Configuration error in SETUP.

In SETUP, disable
decompression of expansion
ROM on unnecessary optional
PCI cards.

0B45 System Configuration

Data Write error

Configuration error in
SETUP.

CPU/PCI module board is
faulty.

Reset the setting by
selecting [Yes] at [Reset
Configuration Data]

Replace the CPU/PCI
module board.

0B47 Missing date and time

synchronization

The date and time are
incorrect due to a
communication error between
BMCs.

Restart the system.

Re-set the date and time in
SETUP.

If the error persists, replace the
PCI module board.

0B49 BMC Issued Reset

Command, but failed
System Reset

System cannot be reset by
BMC’s reset command.

Replace PCI module board.

0B6E DIMMs are installed out

of order

DIMM is faulty.

Replace DIMM.

0B70 The error occurred

during temperature
sensor reading

SMBus device is faulty.

SMBus is faulty.

Replace the CPU/PCI module
or back panel board.

Advertising