Troubleshooting 7-11 – NEC EXPRESS 320Lb-R User Manual

Page 211

Advertising
background image

Troubleshooting 7-11

STATUS LED

Indication

Color

State

Suspected

module

Explanation Procedure

CPU2 +2.5VcAlm
00

Amber Blink CPU module #2 2.5-V power voltage alarm

(lower limit)

CPU2 +2.5VcAlm
02

Amber

Lit

CPU module #2 Fatal 2.5-V power voltage

alarm (lower limit)

CPU2 +2.5VcAlm
07

Amber Blink CPU module #2 2.5-V power voltage alarm

(upper limit)

CPU2 +2.5VcAlm
09

Amber

Lit

CPU module #2 Fatal 2.5-V power voltage

alarm (upper limit)

CPU2 +3.3vAlm
00

Amber Blink CPU module #2

3.3-V power voltage alarm
(lower limit)

CPU2 +3.3vAlm
02

Amber

Lit

CPU module #2 Fatal

3.3-V power voltage

alarm (lower limit)

CPU2 +3.3vAlm
07

Amber Blink CPU module #2

3.3-V power voltage alarm
(upper limit)

CPU2 +3.3vAlm
09

Amber

Lit

CPU module #2 Fatal

3.3-V power voltage

alarm (upper limit)

CPU2 +3.3vsAlm
00

Amber Blink CPU module #2

3.3-V power voltage alarm
(lower limit)

CPU2 +3.3vsAlm
02

Amber

Lit CPU module #2 Fatal

3.3-V power voltage

alarm (lower limit)

CPU2 +3.3vsAlm
07

Amber Blink CPU module #2

3.3-V power voltage alarm
(upper limit)

CPU2 +3.3vsAlm
09

Amber

Lit

CPU module #2 Fatal

3.3-V power voltage

alarm (upper limit)

CPU2 +5.0vAlm
00

Amber Blink CPU module #2 5-V power voltage alarm

(lower limit)

CPU2 +5.0vAlm
02

Amber

Lit

CPU module #2 Fatal 5-V power voltage alarm

(lower limit)

CPU2 +5.0vAlm
07

Amber Blink CPU module #2 5-V power voltage alarm

(upper limit)

CPU2 +5.0vAlm
09

Amber

Lit

CPU module #2 Fatal 5-V power voltage alarm

(upper limit)

CPU2
+5.0vsAlm00

Amber Blink CPU module #2 5-V power voltage alarm

(lower limit)

CPU2
+5.0vsAlm02

Amber

Lit

CPU module #2 Fatal 5-V power voltage alarm

(lower limit)

CPU2
+5.0vsAlm07

Amber Blink CPU module #2 5-V power voltage alarm

(upper limit)

CPU2
+5.0vsAlm09

Amber

Lit

CPU module #2 Fatal 5-V power voltage alarm

(upper limit)

CPU2 broken

Green

Blink CPU module #2 CPU module breakdown

Contact your sales
agent.

CPU2 FAN Alm 01 Amber Blink CPU module #2 Cooling fan 1 alarm
CPU2 FAN Alm 03 Amber Blink CPU module #2 Cooling fan 2 alarm
CPU2 FAN Alm 04 Amber Blink CPU module #2 Cooling fan 3 alarm

Check to see if dust is
accumulated on the
internal fans. Check also
if the fan cables are
connected securely. If
not solved by the above,
contact your sales agent.

CPU2 offline

Green Blink

CPU module #2 The CPU module has been

logically disconnected.

Start the PCI module by
ft sever utility or
dismount and remount
that module. If not
solved by the above,
contact your sales
agent.