NEC EXPRESS 320Lb-R User Manual

Page 284

Advertising
background image

8-46 System Upgrade

PCI Board Status LED Indications

LED
indications

Description Action

Green

Duplex is specified,
however, the server
works in simplex
mode.

Configure duplex.
Reapply the driver.

The PCI board is
properly installed and
operating in
non-duplex mode.
(Does not depend on
simplex or duplex
mode.)

In non-duplex mode, no specific problem occurs.

The PCI board is
properly installed and
duplex is configured.

The system is operating normally in duplex mode.

Off

The PCI board is not
installed yet, the PCI
board is installed
incorrectly, or the
power is not supplied.

Mount the PCI board correctly.
If the PCI board was not mounted, there is no
problem.
Check the condition of power unit.
Remount the PCI module.

In the process of
configuring or
canceling the duplex
mode.

Wait for a while until the indication changes. If the
indication does not change,

check the status of the

installed PCI board slot using NEC ESMPRO
Manager.

Red

Although the PCI
board is mounted, it is
offline or not
functioning.

Make the installed PCI board slot online from NEC
ESMPRO Manager.
Mount the PCI board correctly.

Advertising