Troubleshooting 7-5 – NEC EXPRESS 320Lb-R User Manual

Page 205

Advertising
background image

Troubleshooting 7-5

STATUS LED

Indication

Color

State

Suspected

module

Explanation Procedure

Cor0 +5.0vAlm
09

Amber

Lit

PCI module #1

Fatal

5-V power voltage alarm

(upper limit)

Cor0 +5.0vsAlm
00

Amber Blink PCI module #1

5-V power voltage alarm
(lower limit)

Cor0 +5.0vsAlm
02

Amber

Lit PCI module #1

Fatal

5-V power voltage alarm

(lower limit)

Cor0 +5.0vsAlm
07

Amber Blink PCI module #1

5-V power voltage alarm
(upper limit)

Cor0 +5.0vsAlm
09

Amber

Lit

PCI module #1

Fatal

5-V power voltage alarm

(upper limit)

Cor0 -12vAlm 00 Amber Blink PCI module #1

-12-V power voltage alarm
(lower limit)

Cor0 -12vAlm 02 Amber

Lit

PCI module #1

Fatal -12-V power voltage
alarm (lower limit)

Cor0 -12vAlm 07 Amber Blink PCI module #1

-12-V power voltage alarm
(upper limit)

Contact your sales agent.

Cor0 -12vAlm 09 Amber

Lit

PCI module #1

Fatal -12-V power voltage
alarm (upper limit)

Cor0 Bus PERR
01

Green

Blink PCI module #1

PCI bus parity error

Cor0 Bus SERR
01

Green

Blink PCI module #1

Fatal PCI bus error

Cor0 CLK Alm 00 Amber Blink CLOCK

board

Clock alarm (lower limit)

Cor0 CLK Alm 02 Amber

Lit CLOCK

board

Fatal Clock alarm (lower
limit)

Cor0 CLK Alm 07 Amber Blink CLOCK

board

Clock alarm (upper limit)

Cor0 CLK Alm 09 Amber

Lit CLOCK

board

Fatal Clock alarm (upper
limit)

Contact your sales agent.

Cor0 FAN Alm 01 Amber Blink PCI module #1

Cooling fan1 alarm

Cor0 FAN Alm 02 Amber Blink PCI module #1

Cooling fan2 alarm

Cor0 FAN Alm 03 Amber Blink PCI module #1

Cooling fan3 alarm

Cor0 FAN Alm 04 Amber Blink PCI module #1

Cooling fan4 alarm

Cor0 FAN Alm 05 Amber Blink PCI module #1

Cooling fan5 alarm

Check to see if dust is
accumulated on the
internal fans. Check also if
the fan cables are
connected securely. If not
solved by the above,
contact your sales agent.

Cor0 offline

Green

Blink PCI module #1

PCI module logically isolated Start the PCI module by ft

sever utility or dismount
and remount that module.
If not solved by the above,
contact your sales agent.

Cor0 removed

Green

Blink PCI module #1

PCI module detached

Dismount and remount the
PCI module. If not solved
by the above, contact your
sales agent.

Cor0 Temp Alm
00

Amber Blink PCI module #1

Temperature alarm (lower
limit)

Cor0 Temp Alm
02

Amber

Lit

PCI module #1

Fatal temperature alarm
(lower limit)

Cor0 Temp Alm
07

Amber Blink PCI module #1

Temperature alarm (upper
limit)

Cor0 Temp Alm
09

Amber

Lit

PCI module #1

Fatal temperature alarm
(upper limit)

Check to see if dust is
accumulated on the
internal fans. Check also if
the fan cables are
connected securely. If not
solved by the above,
contact your sales agent.