7-12 Troubleshooting

STATUS LED

Indication

Color State

Suspected

module

Explanation Procedure

CPU2 removed

Green

Blink CPU module #2 The CPU module has come

off.

Dismount and remount
the PCI module. If not
solved by the above,
contact your sales
agent.

CPU2 Temp Alm
00

Amber

Blink CPU module #2 Temperature alarm (lower

limit)

CPU2 Temp Alm
02

Amber

Lit

CPU module #2 Fatal temperature alarm (lower

limit)

CPU2 Temp Alm
07

Amber

Blink CPU module #2 Temperature alarm (upper

limit)

CPU2 Temp Alm
09

Amber

Lit

CPU module #2 Fatal temperature alarm

(upper limit)

Check to see if dust is
accumulated on the
internal fans. Check also
if the fan cables are
connected securely. If
not solved by the above,
contact your sales
agent.

CPU2 VccpAlm 00 Amber Blink CPU module #2 CPU operating voltage alarm

(lower limit) (VCCP)

CPU2 VccpAlm 02 Amber

Lit

CPU module #2 Fatal CPU operating voltage

alarm (lower limit) (VCCP)

CPU2 VccpAlm 07 Amber Blink CPU module #2 CPU operating voltage alarm

(upper limit) (VCCP)

CPU2 VccpAlm 09 Amber

Lit

CPU module #2 Fatal CPU operating voltage

alarm (upper limit) (VCCP)

CPU2 VttAlm 00 Amber Blink CPU module #2 1.25-V power voltage alarm

(lower limit)

CPU2 VttAlm 02 Amber

Lit

CPU module #2 Fatal 1.25-V power voltage

alarm (lower limit)

CPU2 VttAlm 07 Amber Blink CPU module #2 1.25-V power voltage alarm

(upper limit)

CPU2 VttAlm 09 Amber

Lit

CPU module #2 Fatal 1.25-V power voltage

alarm (upper limit)

Contact your sales
agent.

CPU20 TempAlm
00

Amber

Blink CPU module #1 CPU#1 temperature alarm

(lower limit)

CPU20 TempAlm
02

Amber

Lit

CPU module #1 Fatal CPU#1 temperature

alarm (lower limit)

CPU20 TempAlm
07

Amber

Blink CPU module #1 CPU#1 temperature alarm

(upper limit)

CPU20 TempAlm
09

Amber

Lit

CPU module #1 Fatal CPU#1 temperature

alarm (upper limit)

CPU21 TempAlm
00

Amber

Blink CPU module #2 CPU#2 temperature alarm

(lower limit)

CPU21 TempAlm
02

Amber

Lit

CPU module #2 Fatal CPU#2 temperature

alarm (lower limit)

CPU21 TempAlm
07

Amber

Blink CPU module #2 CPU#2 temperature alarm

(upper limit)

CPU21 TempAlm
09

Amber

Lit

CPU module #2 Fatal CPU#2 temperature

alarm (upper limit)

Check to see if dust is
accumulated on the
internal fans. Check also
if the fan cables are
connected securely. If
not solved by the above,
contact your sales
agent.

= D =

DUMP Request!

Off

-

DUMP switch request

Contact your sales
agent.

= F =

FRB Processing Off

-

During POST execution or OS
start processing

The server is operating
normally.