5.9 Other settings affecting the fishfinder image

The system automatically adjusts the following settings in order to optimize the
fishfinder image:

• Operating frequency.
• Gain modes (Gain, Color Gain, TVG)
• Power setting.
They should not ordinarily require adjustment. You can however make adjustments
manually if required.

Operating frequency modes

The operating frequency is indicated in the status bar. You can choose to either set the
frequency to automatic (default) or manual.

Automatic frequency

When operating in automatic frequency, your DSM automatically changes the
frequency from 200 kHz to 50 kHz as your depth increases and from 50kHz to 200 kHz
as your depth decreases. This mode is useful for automatically searching for the
bottom and is the normal mode of operation.

Manual frequency

Manual frequency allows you to manually set the system to either a single or dual
frequency mode:

Single frequency mode
This mode sets the transducer to ping at a single frequency:

50 kHz - scans a wide area and penetrates water well. Use this setting when you

are in deep water and the DSM is locked onto a shallow target e.g. very large shoal
of fish or you are in very shallow water (<30 feet) and you need to see better fish
targets (wider cone angle),or:

200 kHz - scans a narrow area but produces more detail. Use this setting when you

are in deep water and the 200 kHz signal is so strong that you want to retain this
higher resolution picture. It is good for finding fish that are near the bottom or close
together.

To select a single frequency:

T

Note:

Changing the frequency in a single fishfinder window will automatically change

all other fishfinder windows to that frequency.

D7353-2

Toggle to required
frequency

FREQUENCY

AUTO MAN

FREQ MODE

SINGLE DUAL

FISHFINDER

SETTINGS...

SELECTED FREQ

200 50 BOTH

81221_4.book Page 114 Tuesday, February 28, 2006 5:24 PM