8.7. High-Pass Filter Settings

ON

The high-pass filter function can be enabled or disabled for the displayed channel by using the
function ON/OFF key even when any of the following screens is displayed. The function ON/OFF
Indicator lights when enabled (ON).

Cutoff frequency

Q

Input trim settings (previous page)

Equalizer settings (next page)

[ I N 1 ] H P F

F R E Q

6 0 H z

[ I N 1 ] H P F

Q

0 . 7 0 7

8.7.1. Cutoff frequency settings

[ I N

1 ] H P F

F R E Q

6 0 H z

PARAMETER

PUSH-ENTER

CHANGE

• Rotate the Setting knob to set the high-pass filter cutoff

frequency.
Parameter setting range: 20 Hz – 20 kHz in 1/24 octave steps
Note: Slope is fixed at 12 dB/oct.

• Pressing an Input channel selector key permits the high-pass

filter to be set for that channel. The [IN 1] indication changes to
the selected channel number indication.

• The setting screen reverts to the Input/Output Gain Setting

screen when the

shift key is pressed.

8.7.2. Q settings

[ I N

1 ] H P F

Q

0 . 7 0 7

PARAMETER

PUSH-ENTER

CHANGE

• Rotate the Setting knob to set the high-pass filter Q.

Parameter setting range: 0.500 – 2.563 (51 points)

• Pressing an Input channel selector key permits the high-pass

filter to be set for that channel. The [IN 1] indication changes to
the selected channel number indication.

[Screen display operations]

Advertising