TOA Electronics D-901 User Manual

Page 93

Advertising
background image

93

20.13. D-961SP Digital Output Module (Optional)

Contact Input

COM + Terminals 1 – 8: Open voltage: 5 V DC, short-circuit: 5 mA,

10-pin removable terminal block

Preset Memory

Any preset memory can be recalled.

Selection

Control method: No-voltage make of over 100 ms or

no-voltage make single pulse of over 100 ms

Volume

Volume can be turned UP or DOWN for any input and output channels.
Control system: 1 step variation for no-voltage make single pulse of over

100 ms
1 step continuous operation for every 70 ms for no-voltage
make of over 100 ms. Can be reset when at break.

Variable range: –

∞ dB to +10 dB

Channel

Any input/output channels can be turned ON and OFF.
Control method: No-voltage make of over 100 ms or

no-voltage make single pulse of over 100 ms

Stereo Selection

Any stereo input can be selected.
Control method: No-voltage make of over 100 ms or

no-voltage make single pulse of over 100 ms

Contact Output

COM + Terminals 1 – 8: No-voltage make contact input,

contact capacity: 24 V DC, 100 mA
removable terminal block

Finish

Panel: Pre-coated steel plate, black (30% glossy)

Dimensions

35 (w) x 119.5 (h) x 178.4 (d) mm

Weight

125 g

Control

• Accessories
10-pin removable terminal plug (preinstalled on the unit) ......... 2

20.14. D-981 Remote Control Module (Optional)

Note: The design and specifications are subject to change without notice for improvement.

Output

Stereo 2 channels (with splitter, each pair of optical output and coaxial output
in parallel),
0.5 V (p-p), 75

Ω, Coaxial RCA jack x 2

Square optical connector x 2

Applicable Format

S/PDIF (2 channel multiplexed)

Sampling Frequency

48 kHz

Finish

Panel: Pre-coated steel plate, black (30% glossy)

Dimensions

35 (w) x 119.5 (h) x 178.4 (d) mm

Weight 130

g