[Q settings]

[ O U T 1 ] F I L T E R 1

Q

1 . 0 0 0

PARAMETER

PUSH-ENTER

CHANGE

• The Q setting can only be performed when HPF-12 dB is

selected.

• Rotate the Setting knob to set the Q.

Parameter setting range: 0.500 – 2.563 (51 points)

• Pressing an Output channel selector key permits the filter to be

set for that channel. The [OUT 1] indication changes to the
selected channel number indication.

9.4.3. Low-pass filter

[ O U T 1 ] F I L T E R 1

T Y P E L P F - 6 d B

PARAMETER

PUSH-ENTER

CHANGE

• Rotate the Setting knob to select either LPF-6 dB or LPF-12 dB,

and enter the Low-Pass Filter setting screen.
The indications of 6 dB and 12 dB represent the slope: 6 dB/oct
and 12 dB/oct, respectively.

• Setting items, parameter setting ranges and operations are the

same as those for the high-pass filter.

9.4.4. High shelving filter

[ O U T 1 ] F I L T E R 1

T Y P E H - S h e l v

PARAMETER

PUSH-ENTER

CHANGE

• Rotate the Setting knob to select H-Shelv and enter the High

Shelving Filter setting screen.

• Pressing an Output channel selector key permits the filter to be

set for that channel. The [OUT 1] indication changes to the
selected channel number indication.

• The setting screen reverts to the Input/Output Gain Setting

screen when the

shift key is pressed.

[Roll-off frequency settings]

[ O U T 1 ] F I L T E R 1

F R E Q

6 . 0 0 k H z

PARAMETER

PUSH-ENTER

CHANGE

• Rotate the Setting knob to set the roll-off frequency.

Parameter setting range: 6 – 20 kHz in 1/24 octave steps

• Pressing an Output channel selector key permits the filter to be

set for that channel. The [OUT 1] indication changes to the
selected channel number indication.

[Gain settings]

[ O U T 1 ] F I L T E R 1

G A I N

+ 0 . 0 d B

PARAMETER

PUSH-ENTER

CHANGE

• Rotate the Setting knob to set the gain.

Parameter setting range: –15 to +15 dB in 0.1 dB steps

• Pressing an Output channel selector key permits the filter to be

set for that channel. The [OUT 1] indication changes to the
selected channel number indication.

9.4.5. Low shelving filter

[ O U T 1 ] F I L T E R 1

T Y P E L - S h e l v

PARAMETER

PUSH-ENTER

CHANGE

• Rotate the Setting knob to select L-Shelv and enter the Low

Shelving Filter setting screen.

• Setting items and operations are the same as those for the high

shelving filter.

• Parameter setting range

Gain: –15 to +15 dB in 0.1 dB steps
Roll-off frequency: 20 – 500 Hz in 1/24 octave steps