9.4.1. Parametric equalizer

[ O U T 1 ] F I L T E R 1

T Y P E

P E Q

PARAMETER

PUSH-ENTER

CHANGE

• Rotate the Setting knob to select PEQ and enter the Parametric

Equalizer setting screen.

• Pressing an Output channel selector key permits the filter to be

set for that channel. The [OUT 1] indication changes to the
selected channel number indication.

• The setting screen reverts to the Input/Output Gain Setting

screen when the

shift key is pressed.

[Gain settings]

[ O U T 1 ] F I L T E R 1

G A I N

+ 0 . 0 d B

PARAMETER

PUSH-ENTER

CHANGE

• Rotate the Setting knob to set the gain.

Parameter setting range: –15 to +15 dB in 0.1 dB steps

• Pressing an Output channel selector key permits the filter to be

set for that channel. The [OUT 1] indication changes to the
selected channel number indication.

[Center frequency settings]

[ O U T 1 ] F I L T E R 1

F R E Q

1 . 0 0 k H z

PARAMETER

PUSH-ENTER

CHANGE

• Rotate the Setting knob to set the center frequency.

Parameter setting range: 20 Hz – 20 kHz in 1/24 octave steps

• Pressing an Output channel selector key permits the filter to be

set for that channel. The [OUT 1] indication changes to the
selected channel number indication.

[Q settings]

[ O U T 1 ] F I L T E R 1

Q

0 . 2 6 7

PARAMETER

PUSH-ENTER

CHANGE

• Rotate the Setting knob to set the Q.

Parameter setting range: 0.267 – 69.249 (96 points)

• Pressing an Output channel selector key permits the filter to be

set for that channel. The [OUT 1] indication changes to the
selected channel number indication.

9.4.2. High-pass filter

[ O U T 1 ] F I L T E R 1

T Y P E H P F - 6 d B

PARAMETER

PUSH-ENTER

CHANGE

• Rotate the Setting knob to select either HPF-6 dB or HPF-12 dB

and enter the High-Pass Filter setting screen.
The indications of 6 dB and 12 dB represent the slope: 6 dB/oct
and 12 dB/oct, respectively.

• Pressing an Output channel selector key permits the filter to be

set for that channel. The [OUT 1] indication changes to the
selected channel number indication.

• The setting screen reverts to the Input/Output Gain Setting

screen when the

shift key is pressed.

[Cutoff frequency settings]

[ O U T 1 ] F I L T E R 1

F R E Q

1 . 0 0 k H z

PARAMETER

PUSH-ENTER

CHANGE

• Rotate the Setting knob to set the cutoff frequency.

Parameter setting range: 20 Hz – 20 kHz in 1/24 octave steps

• Pressing an Output channel selector key permits the filter to be

set for that channel. The [OUT 1] indication changes to the
selected channel number indication.