12.7. RS-232C Port Settings

[ U T Y ]

R S - 2 3 2 C

M O D E

P C

C T R L

PARAMETER

PUSH-ENTER

CHANGE

• Rotate the Setting knob to select the mode that matches the type

of equipment connected to the unit's RS-232C port.

UPDATE: A PC is connected to update the unit's firmware

using the utility program. (Refer to p. 74.)

REMOTE: A conventional remote controller (AMX, Crestron,

etc.) is connected.

PC CTRL: A PC is connected to control the unit using the

dedicated setting software program (to be
downloaded from our International site, see
below).

Tips
• While the D-901 is communicating with a PC, the front-mounted

system lock indicator flashes.

• In the above status, attempting to change settings with the

front-mounted knobs or keys notifies the operator of prohibited
operation by way of the indication shown below.

Protect settings (p. 68)

[ U T Y ] R S - 2 3 2 C

MO D E N O N E

Control mode
selection

RS-232C transmission
rate

All input/output channel gain confirmation (next page)

[ U T Y ] R S - 2 3 2 C

1 1 5 2 0 0 b p s

12.7.1. Control mode selection

[ U T Y ]

R S - 2 3 2 C

1 1 5 2 0 0 b p s

PARAMETER

PUSH-ENTER

CHANGE

• Rotate the Setting knob to set the RS-232C transmission rate.

Parameter setting range: 115200, 38400, 19200, 9600 bps

12.7.2. RS-232C transmission rate settings

P C

C o n t r o l

M o d e

K e y

L o c k e d

• To enforce the termination of communications with the PC,

press the Setting knob holding down the Function ON/OFF key.

• The control protocol and setting software program are available

for download at our website:
http://www.toa-products.com/international/

Tip
Settings are automatically saved as system data, and
setting status is maintained even if the power is turned
off.