Cooling fan operating status confirmation, Firmware version confirmation – TOA Electronics D-901 User Manual

Page 73

Advertising
background image

73

• Slot numbers are displayed on the upper row, and the inserted module

types on the lower row.

A: D-921E or D-921F Microphone/line input module
B: D-922E or D-922F Microphone/line input module
C: D-936R Stereo input module
D: D-971E or D-971M Line output module
E: D-971R Line output module (RCA connector)
F: D-981 Remote control module
I: D-923AE Digital input module
J: D-937SP Digital input module
K: D-961SP Digital output module
L: D-972AE Digital output module
M: D-983 Remote control module
N: D-984VC VCA control module
–: Blank

: A wrong module installed

• When a wrong module is inserted into a slot, the initial screen that

indicates the relevant slot with "

" mark appears after the unit's power

is switched ON as shown below.

S L O T :

1 2 3 4 5 6 7 8 9

T Y P E :

A A B B C – D E F

E R R O R

C H E C K

S L O T

12.10.2. All slots confirmation

12.11. Cooling Fan Operating Status Confirmation

[ U T Y ]

F A N

R U N N I N G

• The operating status of the rear-mounted cooling fan can be confirmed

on the screen.

Normal operation:

Operation failure:

• When "ERROR" is displayed, check to be sure that the fan exhaust

vent is not blocked or that a foreign object has not jammed the vent.
The fan is detected as having failed when it stops or if its rotation
speed is extremely slow. In such cases contact your TOA dealer.

• If the fan rotation speed decreases dramatically, the display switches

over to the cooling fan failure screen even when another screen is
displayed. Pressing the Setting knob turns off the failure indication.

Module type confirmation (previous page)

[ U T Y ]

F A N

R U N N I N G

[ U T Y ]

F A N

W A R N I N G

12.12. Firmware Version Confirmation

[ U T Y ]

V E R S I O N

3 . 0 0 . 0 0 0

• The firmware version number can be confirmed.