Connector connections

Step 1. Detach the unit's rear-mounted input/output

connector (removable terminal plug) from the unit.

Step 2. Loosen the terminal screw, then insert the cable.

Step 3. Retighten the terminal screw. (Pull on the cable to

ensure it is securely connected.)

Step 4. Remount the input/output connector to the unit.

Tip
Recommended slotted screwdriver type: Screwdriver with
blade that is 3 mm in width

Tightens

Loosens

Terminal screw

Slotted screwdriver

Shielded cable

Removable

terminal plug

2

2

3

Bit shape 3 mm

16.3. Removable Terminal Plug Connection

Cautions

• Be sure to use shielded cables for audio signal lines.

• Avoid soldering stranded or shielded cable, as contact resistance may increase when the cable is tightened

and the solder is crushed, possibly resulting in an excessive rise in joint temperatures.

Cable end treatment

Solid or stranded cable

Shielded cable

7 mm

7 mm

20 mm

16.4. Ferrite Cable Clamp Attachment

(For D-972AE only)

To reduce electromagnetic noise, place the supplied ferrite
clamp over each digital output cable when making a cable
connection to the D-972AE Digital Output Module.

Install one ferrite clamp per digital output cable.