Delay time settings – TOA Electronics D-901 User Manual

Page 51

Advertising
background image

51

9.5.3. Attack time settings

[ O U T 1 ] C O M P

A T T A C K 1 0 . 0 m s

PARAMETER

PUSH-ENTER

CHANGE

• Rotate the Setting knob to set the attack time.

Parameter setting range: 0.2 ms – 5 s (Refer to p. 85 for more

information.)

• Pressing an Output channel selector key permits the compressor

attack time to be set for that channel. The [OUT 1] indication
changes to the selected channel number indication.

9.5.4. Release time settings

[ O U T 1 ] C O M P

R E L E A S E

5 0 0 m s

PARAMETER

PUSH-ENTER

CHANGE

• Rotate the Setting knob to set the release time.

Parameter setting range: 10 ms – 5 s (Refer to p. 85 for more

information.)

• Pressing an Output channel selector key permits the compressor

release time to be set for that channel. The [OUT 1] indication
changes to the selected channel number indication.

9.5.5. Makeup gain settings

[ O U T 1 ] C O M P

G A I N

+ 0 d B

PARAMETER

PUSH-ENTER

CHANGE

• Rotate the Setting knob to set the makeup gain.

Parameter setting range: –INF (–

∞) to +10 dB in 1 dB steps.

• Pressing an Output channel selector key permits the

compression makeup gain to be set for that channel. The [OUT 1]
indication changes to the selected channel number indication.

9.6. Delay Time Settings

[ O U T 1 ] D E L A Y

O F F

0 . 0 0 0 m s

ON

PARAMETER

PUSH-ENTER

CHANGE

• Rotate the Setting knob to set the delay time.

Parameter setting range: 0 – 682.6 ms in 0.021 ms steps

• Press the function ON/OFF key to enable or disable the delay

function.

• Pressing an Output channel selector key permits the delay time

to be set for that channel. The [OUT 1] indication changes to the
selected channel number indication.

• The setting screen reverts to the Input/Output Gain Setting

screen when the

shift key is pressed.

Compressor settings
(previous page)

Advertising