Compressor settings, Q settings, Threshold level settings – TOA Electronics D-901 User Manual

Page 50

Advertising
background image

50

[Q settings]

[ O U T 1 ] F I L T E R 1

Q

0 . 2 6 7

PARAMETER

PUSH-ENTER

CHANGE

• Rotate the Setting knob to set the Q.

Parameter setting range: 0.267 – 69.249 (96 points)

• Pressing an Output channel selector key permits the filter to be

set for that channel. The [OUT 1] indication changes to the
selected channel number indication.

[Center frequency settings]

[ O U T 1 ] F I L T E R 1

F R E Q

1 . 0 0 k H z

PARAMETER

PUSH-ENTER

CHANGE

• Rotate the Setting knob to set the center frequency.

Parameter setting range: 20 Hz – 20 kHz in 1/24 octave steps

• Pressing an Output channel selector key permits the filter to be

set for that channel. The [OUT 1] indication changes to the
selected channel number indication.

9.5. Compressor Settings

ON

When any of the following screens is displayed, the compression function for the displayed channel
can be enabled or disabled with the function ON/OFF key. When enabled (ON), the function
ON/OFF Indicator lights.

[Screen display operations]

Filter settings (P. 45)

Delay time settings (next page)

Ratio

Threshold level

Attack time

Release time

Makeup gain

[ O U T 1 ] C OM P

T H R E S H + 0 d B

[ O U T 1 ] C OM P

R A T I O 1 : 1

[ O U T 1 ] C OM P

G A I N + 0 d B

[ O U T 1 ] C OM P

A T T A C K 1 0 . 0 m s

[ O U T 1 ] C OM P

R E L E A S E

5 0 0 m s

9.5.1. Threshold level settings

[ O U T 1 ] C O M P

T H R E S H + 0 d B

PARAMETER

PUSH-ENTER

CHANGE

• Rotate the Setting knob to set the threshold level.

Parameter setting range: –20 to +20 dB in 1 dB steps

• Pressing an Output channel selector key permits the compressor

threshold level to be set for that channel. The [OUT 1] indication
changes to the selected channel number indication.

• The setting screen reverts to the Input/Output Gain Setting

screen when the

shift key is pressed.

9.5.2. Ratio settings

[ O U T 1 ] C O M P

R A T I O 1 : 1

PARAMETER

PUSH-ENTER

CHANGE

• Rotate the Setting knob to set the ratio.

Parameter setting range: 1:1, 2:1, 3:1, 4:1, 8:1, 12:1, 20:1, INF

(

∞):1

• Pressing an Output channel selector key permits the

compression ratio to be set for that channel. The [OUT 1]
indication changes to the selected channel number indication.

Advertising