Auto-leveler settings – TOA Electronics D-901 User Manual

Page 33

Advertising
background image

33

8.11. Auto-Leveler Settings

(only when the auto-leveler mode is selected in Section 8.9.)

The auto-leveler function performs to keep the output level constant by suppressing the change of sound
volume. Setting the target level (the constant level to be automatically adjusted to) and the maximum gain (the
amount of gain to bring the lower level to the target level) automatically compensates for the input level. Note
that setting an excessive amount of gain increases the input sensitivity, easily causing feedback.

Note: No following displays appear when the compressor mode is selected.

ON

When any of the following screens is displayed, the auto-leveler function for the displayed channel
can be enabled or disabled with the function ON/OFF key. When enabled (ON), the function
ON/OFF Indicator lights.

Maximum gain

Target level

Attack time

Release time

Compressor/auto-leveler mode selection (p. 31)

Level sense settings (next page)

[ I N 1 ] L E V E L E R

T A R GE T

+ 0 d B

[ I N 1 ] L E V E L E R

M A X G A I N + 0 d B

[ I N 1 ] L E V E L E R

A T T A C K

5 0 0 m s

[ I N 1 ] L E V E L E R

R E L E A S E

1 . 0 0 s

[Screen display operations]

8.11.1. Target level settings

[ I N

1 ] L E V E L E R

T A R G E T

+ 0 d B

PARAMETER

PUSH-ENTER

CHANGE

• Rotate the Setting knob to set the target level.

Parameter setting range: –20 to +10 dB in 1 dB steps

• Pressing an Input channel selector key set for the auto-leveler

mode permits the auto-leveler target level to be set for that
channel. The [IN 1] indication changes to the selected channel
number indication.

• The setting screen reverts to the Input/Output Gain Setting

screen when the

shift key is pressed.

8.11.2. Maximum gain settings

[ I N

1 ] L E V E L E R

M A X

G A I N

+ 0 d B

PARAMETER

PUSH-ENTER

CHANGE

• Rotate the Setting knob to set the maximum gain.

Parameter setting range: 0 to +20 dB in 1 dB steps

• Pressing an Input channel selector key set for the auto-leveler

mode permits the auto-leveler maximum gain to be set for that
channel. The [IN 1] indication changes to the selected channel
number indication.

8.11.3. Attack time settings

[ I N

1 ] L E V E L E R

A T T A C K

5 0 0 m s

PARAMETER

PUSH-ENTER

CHANGE

• Rotate the Setting knob to set the attack time.

Parameter setting range: 10 ms – 10 s (Refer to p. 86 for more

information.)

• Pressing an Input channel selector key set for the auto-leveler

mode permits the auto-leveler attack time to be set for that
channel. The [IN 1] indication changes to the selected channel
number indication.