36

8.13.3. Depth settings

[ I N

1 ] G A T E

D E P T H

– 2 0 d B

PARAMETER

PUSH-ENTER

CHANGE

• Rotate the Setting knob to set the depth (signal attenuation when

the gate is closed).
Parameter setting range: –INF (–

∞) to 0 dB in 1 dB steps

• Pressing an Input channel selector key permits the gate depth to

be set for that channel. The [IN 1] indication changes to the
selected channel number indication.

8.13.4. Hold time settings

[ I N

1 ] G A T E

H O L D

1 0 . 0 m s

PARAMETER

PUSH-ENTER

CHANGE

• Rotate the Setting knob to set the hold time (the interval the gate

is kept open when an input signal level drops below the closing
threshold level).
Parameter setting range: 10 ms – 10 s (Refer to p. 86 for more

information.)

• Pressing an Input channel selector key permits the gate hold time

to be set for that channel. The [IN 1] indication changes to the
selected channel number indication.

8.13.5. Attack time settings

[ I N

1 ] G A T E

A T T A C K

1 0 . 0 m s

PARAMETER

PUSH-ENTER

CHANGE

• Rotate the Setting knob to set the attack time (the time required

for the gate to open).
Parameter setting range: 10 ms – 10 s (Refer to p. 86 for more

information.)

• Pressing an Input channel selector key permits the gate attack

time to be set for that channel. The [IN 1] indication changes to
the selected channel number indication.

8.13.6. Release time settings

[ I N

1 ] G A T E

R E L E A S E

1 0 . 0 m s

PARAMETER

PUSH-ENTER

CHANGE

• Rotate the Setting knob to set the release time (the time required

for attenuation to reach the gain set in the depth setting when the
gate is closed).
Parameter setting range: 10 ms – 10 s (Refer to p. 86 for more

information.)

• Pressing an Input channel selector key permits the gate release

time to be set for that channel. The [IN 1] indication changes to
the selected channel number indication.