TOA Electronics D-901 User Manual

Page 32

Advertising
background image

32

8.10.2. Ratio settings

[ I N

1 ] C O M P

R A T I O

1 : 1

PARAMETER

PUSH-ENTER

CHANGE

• Rotate the Setting knob to set the ratio.

Parameter setting range: 1:1, 2:1, 3:1, 4:1, 8:1, 12:1, 20:1, INF

(

∞):1

• Pressing an Input channel selector key permits the compression

ratio to be set for that channel. The [IN 1] indication changes to
the selected channel number indication.

8.10.3. Attack time settings

[ I N

1 ] C O M P

A T T A C K

1 0 . 0 m s

PARAMETER

PUSH-ENTER

CHANGE

• Rotate the Setting knob to set the attack time.

Parameter setting range: 0.2 ms – 5 s (Refer to p. 85 for more

information.)

• Pressing an Input channel selector key permits the compression

attack time to be set for that channel. The [IN 1] indication
changes to the selected channel number indication.

8.10.4. Release time settings

[ I N

1 ] C O M P

R E L E A S E

5 0 0 m s

PARAMETER

PUSH-ENTER

CHANGE

• Rotate the Setting knob to set the release time.

Parameter setting range: 10 ms – 5 s (Refer to p. 85 for more

information.)

• Pressing an Input channel selector key permits the compression

release time to be set for that channel. The [IN 1] indication
changes to the selected channel number indication.

8.10.5. Makeup gain settings

[ I N

1 ] C O M P

G A I N

+ 0 d B

PARAMETER

PUSH-ENTER

CHANGE

• Rotate the Setting knob to set the makeup gain.

Parameter setting range: –INF (–

∞) to +10 dB, in 1 dB steps

• Pressing an Input channel selector key permits the compression

makeup gain to be set for that channel. The [IN 1] indication
changes to the selected channel number indication.

Advertising