TRENDnet TEG-S3000I User Manual

Page 90

Advertising
background image

88

1Mbps, ingress rate is 500Kbps. The switch will perform flow control or Back

Pressure to confine the ingress rate to meet the specified rate.

„ In: fill in the port effective ingress rate. The valid range is 0 ~ 1000. The unit is

100K. 0: disable rate control. 1 ~ 1000: valid rate value.

„ Out: fill in the port effective egress rate. The valid range is 0~1000. The unit is

100K. 0: disable rate control. 1 ~ 1000: valid rate value.

9. Priority: this static priority based on port, if you set the port is high priority, income

frame from this port always high priority frame.

10. Security: when the port is in security mode, the port will be “locked” without

permission of address learning. Only the incoming packets with SMAC already

existing in the address table can be forwarded normally. User can disable the port

from learning any new MAC addresses, and then use the static MAC addresses

screen to define a list of MAC addresses that can use the secure port.

11. Click

Apply

button to apply all configuration.

12. When you select the port, you can see port current configure shows in below

column.

Port Control interface

Trunking

The Link Aggregation Control Protocol (LACP) provides a standardized means for

exchanging information between Partner Systems on a link to allow their Link

Aggregation Control instances to reach agreement on the identity of the Link

Advertising