Varec TankGate Interface 8315 Series User Manual

Page 23

Advertising
background image

8315 TGI

Hardware

Varec, Inc.

13

For RS-485, set the Hardware Handshaking Switch SW1 to the ‘A’ position. Refer to the following

table:.

Table 2-1:

Tank Gate Interface Communications Cable

The layout for the RS-232 cable between the PC and the Tank Gate Interface is shown in the

following illustrations.

Comm.
Physical
Layer

Hardware
Handshake

SW1
Setting

SW2
Setting

Notes

RS-232

No

A

UP (towards the

RS-232 side)

Use with a PC. Signals at terminal block J5 will

be RS-232

RS-232

Yes

B

UP (towards the

RS-232 side)

Use to communicate to systems that require

Request To Send (RTS) in order to transmit

(Modems, Radios, etc.)
RTS and CTS signals will be available at

terminal block J6

RS-485 Yes

A

DOWN

(towards

the RS-485

side)

Always SW1 set to the A position when using

RS-485..