10 system information (sys) – Varec TankGate Interface 8315 Series User Manual

Page 49

Advertising
background image

8315 TGI

Software Description

Varec, Inc.

39

Application

The SCALER point allows you to perform simple math functions such as conversion of units. The

SCALER point takes the value from user-specified database references, multiplies each by a

constant and adds the three product terms. A constant K may also be factored in. The SCALER

point works in conjunction with parameters that are in floating point format.

4.4.10 System Information (SYS)

The System Information Point lists the hardware and software specifications of the

system. Other information includes the hardware version and any connected devices.

Parameters

The database parameters used by the SYS point are listed and described below:

PntStatus

Byte value indicating status of point Values are:
0: No error
15: Invalid Type for PntRef
16 Invalid Number for PntRef
17 Invalid Param for PntRef
19: PntRef point does not exist
25: PntRef is not defined

Elapse

Time the SCALER point last executed.

PntCheckSum

CRC-16 Checksum of point's static Configuration Parameters

Dynamic Parameters

Function

Configuration Parameters

Function

RTUTag

RTUTag can contain 15 bytes of data and can include any printable ASCII

character.

DBFile

The database file name. DBFile is the name of the RCF database

configuration file

DBVer

The database version.

PntEnable

Disable/Enable execution of points. Default is Enable.

Dynamic Parameters

Function

UnitAddr

The Unit Address (SW1) for the 8300 series Tank Gate Interface.

DBPnts

The number of database points defined.

DBSize

The size of the database in bytes.

DBChangeTime

The time of last database modification.

SysVer

The firmware version.

SysCheckSum

The system checksum.

HardVer

The PCB hardware version.

PSDVer

The programmable logic version.

PntCheckSum

CRC-16 Checksum for point's static Configuration Parameters.