11

The Xantrex Battery Monitor also indicates when the battery needs

to be recharged or when the battery is fully charged. These

indications are made using the CHARGE BATTERY FULL indicators

at the bottom of the display or the five-segment bar graph at the top

of the display. In the table below the four possible combinations of

these indicators are explained.

Temperature (°C or °F) displays the present battery

temperature. This readout is automatically activated

when Function F11 is set to AU and the optional

temperature sensor is connected to the Xantrex

Battery Monitor. When connection with the

temperature sensor is lost, the display will show four

dashes (- - - -). The temperature unit can be selected

in Function F15.

CHARGE BATTERY (flashing). The

state-of-charge of the battery has

dropped below the adjusted “discharge

floor” (see Function F05). The battery

needs to be recharged as soon as

possible.

BATTERY FULL (flashing). The

battery is fully charged and the battery

charger possibly operates in the “float”

stage. The charger may be turned off.

The monitor is synchronized with the

battery!

CHARGE BATTERY FULL (flashing).

Charge the battery completely full!

This is displayed when the Xantrex

Battery Monitor needs to be

synchronized with the battery (for

example after a number of charge/

discharge cycles, after a reset or after

power-up).