6 Technical Data

Xantrex Battery Monitor TECHNICAL DATA

Supply voltage range

9 .. 35 VDC

Supply current @Vin=24 VDC

without BL

6 mA

@Vin=12 VDC without BL

8 mA

Input voltage range

0 .. 35 VDC

Input current range

-500 .. +500 A

Battery capacity range

20 .. 2000 Ah

Operating temperature range

0 .. 50 °C

Readout resolution

voltage (0 .. 35 V)

± 0.01 V

current (0 .. 200 A)

± 0.1 A

current (200 .. 500 A)

± 1 A

amp hours (0 .. 200 Ah)

± 0.1 Ah

amp hours (200 .. 2000 Ah)

± 1 Ah

state-of-charge (0 .. 100%)

± 0.1%

time-to-go (0 .. 100 hrs)

± 1 minute

time-to-go (100 .. 240 hrs)

± 1 hr

temperature (0 .. 50 ×C)

± 1 °C

Voltage measurement

accuracy

± 0.3%

Current measurement

accuracy

± 0.4%