If none of the above remedies help to solve your problem, contact

your local dealer for further help.

CHARGE BATTERY or

CHARGE BATTERY

FULL flashes

Charge battery full (equalize/

synchronize your battery with

the monitor)

Check the charged parameters

in Functions F02, F03 and F04

for possible incorrect setting

s.

State-of-charge and/or

time-to-go readout are

not accurate

Check if all current is flowing

through the shunt (the negative

terminal of the battery may only

contain the wire going to the

battery side of the shunt!).

Current sense leads from the

shunt are reversed.

Check battery capacity in

Function F01

Check CEF in Function F09

Check Peukert Exponent in

Function F10

Check Battery temperature in

Function F11

Check Temperature coefficient

in Function F12

Display returns “- - - -” in

temperature readout

Connection with temperature

sensor is lost. Check for failed

connections and/or cable damage.

Battery voltage readout is

highly inaccurate

Check prescaler setting in Function

F16