4 advanced features, History data – Xantrex Technology Xantrex Battery Monitor User Manual

Page 21

Advertising
background image

12

4 Advanced Features

Besides the general functionality as described in the previous

chapter, the Xantrex Battery Monitor offers some additional

advanced features. These features are reviewed in the next three

sections.

History data

The Xantrex Battery Monitor is able to store “special” events as

history data in its memory. The following events are stored as history

data:

STATE OF CHARGE BAR GRAPH.

This bar represents the state of charge

in five steps until the “discharge floor”

(see Function F05) is reached. Five bar

segments represent a fully charged

battery. When the battery is

discharged, the bar disappears and the

message “CHARGE BATTERY” will

appear.

H01

The automatically calculated charge efficiency factor

(CEF).

H02

The average discharge in Ah. This value will be

recalculated after each synchronization.

H03

The deepest discharge in Ah.

H04

Number of charge/discharge cycles.

H05

The number of “synchronizations.” This is the number

of times the battery is fully charged meeting the charged

parameters condition.

H06

The number of full discharges (reaching a state-of-

charge of 0.0%).

H07

The number of under-voltage alarms.

H08

The number of over-voltage alarms.

Advertising