3 instrument connection, 1 vvo directly on the sensor, 2 vvo on the 4 … 20 ma-line – VEGA VVO VEGA Visual Operating User Manual

Page 6: 3 vvo on the vbus-line, Instrument connection, Connection possibility via vegaconnect 2 on hart

Advertising
background image

6

VEGA Visual Operating

+

-

VEGACONNECT 2

to sensor

R = 100

W

Instrument connection

3 Instrument connection

3.1 VVO directly on the sensor

VEGACONNECT
2

VEGACONNECT
2

For connection of the PC directly to the sen-
sor, a VEGACONNECT 2 should be con-
nected as adapter. 2 mm-sockets are
provided on all communication capable
VEGA-sensors, where the two-wire line of
VEGACONNECT 2 can be inserted.

3.2 VVO on the 4 … 20 mA-line

Connection possibility via VEGACONNECT 2
on HART

®

-capable sensors on the

4 … 20 mA-line. It does not matter if the
power supply of the sensor is provided
separately or via the 4 … 20 mA-line.

A digital signal is additionally superimposed
to the 4 … 20 mA-output of the HART

®

-capa-

ble sensor. Note the inner resistor of the
connected processing. If this resistor is
<100

W (e.g. with an indicating instrument),

the digital signal will be damped. In this case
a load resistor of R = 100

W should be looped

into the 4 … 20 mA-line.

With analogue inputs of DCS-systems, this
resistor is in general >100

W, so that there will

be no damping.

3.3 VVO on the VBUS-line

ESC

OK

-

+

1

2

on

100

%

CONNECT

514 V

4 … 20 mA-line with superim-
posed HART

®

-signal

If several sensors are connected via one
BUS-line, VEGACONNECT 2 can be con-
nected to the BUS-line to adjust all other
sensors.