This manual will explain the method using HyperTerminal. If you need to install HyperTerminal,
click start>setting>control panel>add/remove programs. For more precise details on
HyperTerminal installations, please refer to Microsoft Windows Help section.
Attach Parani-BCD110V3 to serial port of host computer and power on the unit.
Launch HyperTerminal. It can be found in start menu >programs >accessories >communication
>HyperTerminal. Select the Serial port that Parani-BCD110V3 is connected to.
Input the same settings into Serial port configuration window as Parani-BCD110V3 settings.
Select the Serial port setting displayed in the Window, please make sure the serial settings in
HyperTerminal are set to the same settings as the Parani-BCD110V3’s serial settings.

Figure 3-11 HyperTerminal

To view the AT commands that are being typed, you will need to enable the local echo option.
Go to File->Properties->Settings->ASCII setup and select the “Echo typed characters locally”
option.
For expanded AT commands, please refer to Appendix A. AT commands.

Example of AT commands
















at

OK
at+btinfo?

000195000144,BCD110v3.0.0-000144,MODE0,STANDBY,0,0,NoFC

OK
at+btinq?

000B5320070E,Promi-MSP_20070E,020300

0009DD500027,LEECOM,1E010C

OK
atd000b5320070e

OK

CONNECT 000B5320070E