B.3.36. at+iosync=nn – SENA Parani-BCD110V3 User Manual

Page 63

Advertising
background image

Sena Technologies, Inc

63

Description

This command sets the DIO change detection sampling. The digital I/O status of
Parani-BCD110V3 can be monitored whenever a monitored digital I/O pin changes
state. The DIO change detection sampling and the Periodic Sampling can be set and
used at the same time. Change is applied without rebooting.
When I/O configuration of all the DIO pins is set as ‘Disabled, the DIO change detection
sampling does not work.

Example

AT+DIOCDS=1


B.3.35. AT+AIOCDS=value,AIO0 Rising edge,AIO0 Falling edge,AIO1 Rising

edge,Aio1 Falling edge

Response

 OK

Purpose

Set AIO changed detection sampling

Parameters

value = 0~10 (Detection period: 0. Disabled, 1. 100ms, 2. 200ms, … 10.
1000ms)
Rising edge = 0~15000 (Unit, 0.1mv)
Falling edge = 0~15000 (Unit, 0.1mv)

Description

This command sets the AIO change detection sampling. The analog I/O values
of Parani-BCD110V3 can be monitored whenever AIO value falls down below
the Falling edge or rises up above the Rising edge. If the Rising edge is greater
than the Falling edge, the AIO value will be monitored when AIO value is
between the Falling edge and the Rising edge.
The AIO change detection sampling and the Periodic Sampling can be set and
used at the same time. Change is applied without rebooting. It works when I/O
configuration of one or more AIO is set as ‘Enabled’.

Example

AT+AIOCDS=1,15000,0,15000,0


B.3.36. AT+IOSYNC=nn

Response

 OK

Purpose

Set DIO synchronization

Parameters

nn = 0/1/2/3 (Default 0)
0 Disabled
1 Synchronization input
2 Synchronization output
3 Synchronization input/Synchronization output

Description

This command sets the DIO synchronization configuration. The DIO synchronization
works well when both devices with single connection mode are connected in I/O
profile.

Example

AT+IOSYNC=0