C.34. s72: bd address of last connected i/o device – SENA Parani-BCD110V3 User Manual

Page 75

Advertising
background image

Sena Technologies, Inc

75

C.31. S61: MAX TX POWER (default 0)


This value describes the peak output power. This Setting is applied after rebooting. (There is a
little deviation according to the devices.)

설정 값

dBm

0

Use chip setting.

1

-6

2

-3

3

0

4

3

5

6

6

10

7

14

8

18


C.32. S63: Reconnect Time Interval (default 20)


This value defines reconnect time interval in case a slave is disconnected in multiple connection
mode. The actual reconnect time interval will be the value multiplied by two in seconds. For
example, if the value is set to 5, the reconnect time interval will be 10 seconds. The value should
be greater than or equal to 20. The master unit will only try to reconnect when its mode is set to
Mode1.

C.33. S71: Remote Escape Sequence (default 45)


The decimal number of the ASCII code of remote escape sequence character can be controlled.
The initial value is 45, the ASCII code of ‘-’.

C.34. S72: BD Address of Last Connected I/O Device


This saves the BD address of the Bluetooth device connected most recently in I/O profile. This
address is used when I/O connection is attempted using AT+IOCONNECT command.

C.35. S82: Enable Deep Sleep (default 0)


S82=0, Deep Sleep Disable

S82=1, Deep Sleep Enable

If Deep Sleep is enabled and there is no data transmission in 1 second, Parani-BCD110V3 will be
in Deep Sleep. Data transmission will wake up Parani-BCD110V3 in Deep Sleep.

* While quiescent current in Standby status where Parani-BCD110V3 do not anything is about
1.24mA, quiescent current in Deep Sleep status is about 0.02mA. Users need to know that there
is data loss when Parani-BCD110V3 comes out of Deep Sleep.