Technical specifications, Jog and linear ramp – GE Industrial Solutions ASTAT-CD Plus User Manual

Page 14

Advertising
background image

3. Technical Specifications

3-5

Linear acceleration and deceleration ramp

Ramp time adjustable (Selectable by parameter "Dxxx" to ON

Low slow (7%) and High slow (14%) speeds

Enabled by parameter "Jxxx" to ON and "jxxx" to LO or HI

Reverse slow speed (20%)

Enabled by parameter "Jxxx" to ON and "rxxx" to ON

Slow speed (7% or 14%)

Enabled by parameter "Jxxx" to ON

Acceleration ramp

Ramp time adjustable

Soft stop (deceleration ramp)

Ramp time adjustable

Slow speed (7% or 14%)

Enabled by parameter "Jxxx" to ON

DC Brake

Current and time adjustables, Enabled by parameter Bxxx to ON, and bxx, Ixxx adjustments

1

8

7

6

5

4

3

2

Linear ramp with T.G. feedback

Slow speed. Basic diagram

Slow speed. Full diagram

1a

3a

Jog and linear ramp

1

1a

% of mot

or full load speed

t

100

4

5

% of mot

or full load speed

8

7

6

t

t

100

TERMINALS

CLOSED

4-57

OPEN

CLOSED

1-57

OPEN

CLOSED

2-57

OPEN

2

3a

3

t

100

% of mot

or full load speed

14

7

20

Advertising