Types and ratings, 2. ul ratings – GE Industrial Solutions ASTAT-CD Plus User Manual

Page 8

Advertising
background image

2. Types and Ratings

2-2

2-2. UL Ratings

(1)

Current

Max.

HEAVY DUTY

STANDARD DUTY

Degree of

Cat. No.

Weight

Cooled

rating

starting

200V

230V

460V

200V

230V

460V

protection

current

A

A

HP

HP

HP

HP

HP

HP

Kg.

Lbs.

14

63

3

3

7.5

3

3

7.5

IP-00

QC2FDP

4.3

9.48

Natural

17

77

3

3

10

3

3

10

IP-00

QC2GDP

4.3

9.48

Natural

22

99

5

7.5

15

5

7.5

15

IP-00

QC2HDP

4.6

10.14

Natural

34

153

7.5

7.5

20

10

10

25

IP-00

QC2IDP

4.6

10.14

Natural

48

216

10

15

30

15

15

30

IP-00

QC2JDP

12.5

27.56

By fan

63

284

15

20

40

20

20

40

IP-00

QC2KDP

12.5

27.56

By fan

72

324

20

20

40

20

25

50

IP-00

QC2LDP

17.0

37.48

By fan

105

473

30

30

60

30

30

75

IP-00

QC2MDP

17.0

37.48

By fan

156

702

40

50

100

50

60

125

IP-00

QC2NDP

45.0

99.20

By fan

240

1080

60

75

150

75

75

200

IP-00

QC2QDP

45.0

99.20

By fan

315

1418

75

100

200

100

125

250

IP-00

QC2RDP

55.0

121.25

By fan

370

1665

100

125

250

125

150

300

IP-00

QC2SDP

55.0

121.25

By fan

500

2250

150

150

350

150

200

400

IP-00

QC2TDP

80.0

176.36

By fan

630

2835

200

200

400

200

250

500

IP-00

QC2UDP

105.0 231.47

By fan

850

3825

250

300

600

300

350

700

IP-00

QC2VDP

120.0 264.54

By fan

Notes:

(1)

=

Ratings in Amps. given for ambient temperature up to 40

°

C and 1000m altitude.

Derate output current by 1.5% /

°

C above 40

°

C.

Derate output current by 1% / 100m above 1000m.

Advertising