Appendix, 2. serial communications – GE Industrial Solutions ASTAT-CD Plus User Manual
Page 32
6. Appendix
The following table indicates the communications setting used by ASTAT-CD Plus to perform data communication via its serial port.
Name
Setting
Description
Baud Rate
9600 bps
Bits per second transmission rate
Parity
None
Data error checking method
Data Bits
8
Number of data bits in each transmission
Start Bits
1
Number of bits to indicate beginning of transmission
Stop Bits
2
Number of bits to indicate ending of transmission
Data
ASCII
Communications protocol used
Handshaking
None
No need to request to send or clear to send
Computer
2
TD
ASTAT-CD Plus
Pin
RS232 cable
6-4
6-2. Serial communications
ASTAT-CD Plus is able to send and receive data through a serial RS232 port. Within this port ASTAT-CD Plus communicates with a host PC.
For RS232 ASCII communications, parameter "XP" must be set to 0.
6-2-1. RS232 port, wiring and communications settings
RS232 is an operating standard of communication only in terms of electrical characteristics (voltage, timing, etc.) while the communication
procedures are defined by ASCII.
The maximum allowed RS232 cable length is 3 meters. ASTAT-CD Plus uses a connector with only 3 pins: TD, RD, SG.
Astat Terminal
Name
TD
Transmit Data
RD
Receive Data
SG
Signal Common
RS232 connector
3
RD
D-SUB9
5
SG