Data messages, Command messages – GE Industrial Solutions AF-300 P11_G11 Ethernet Interface User Manual

Page 21

Advertising
background image

EGD

15

[Consumption 1 DataOffset]

The number of 16-bit words into the data portion of the exchange from
which consumed data is copied. Using different offsets on different
devices allows a single exchange to be sent to a group of devices,
improving network bandwidth utilization and coordination among
devices.

To set the configuration to default, delete the file and restart the drive.

Data Messages

This product defines four EGD exchanges:

Exchange Description
Exchange C1

Consumed exchange 1, this exchange contains control information to the
drive. Data format is described in “Appendix A - EGD, EtherNet/IP IO
Format”.

Exchange P1

Produced exchange 1, this exchange contains operation status monitor
words and frequency output monitor. Data format is described in
“Appendix A - EGD, EtherNet/IP IO Format”.

Exchange P2

Produced exchange 2, this exchange contains control and monitor values
from the drive. The values in this exchange is updated at low priority, e.g.,
other protocols, like Modbus/TCP, are prioritized when requesting data.
Data format is described in “Appendix D - EGD Exchanges”.

Exchange P3

Produced exchange 3, this exchange is used for accessing drive registers
with Command messages and cannot be set up for cyclic production.
Data format is described in “Appendix D - EGD Exchanges”.

Command Messages

Command messages are used for monitoring and control of the module.

The following commands are used for this product:

Command Description
Retrieve Configuration

Returns configuration information for an exchange

Summary

Returns a summary of the exchanges

Capabilities

Returns the supported capabilities of the module

Statistics

Returns the operating statistics of a specified exchange

Read

Returns the contents of one or more continuous groups of memory

Write

Changes the contents of one or more continuous groups of memory

Advertising