Identity object, class 0x01, Services, Class attributes – GE Industrial Solutions AF-300 P11_G11 Ethernet Interface User Manual

Page 45: Instance attributes

Advertising
background image

Appendix C – Ethernet/IP Objects

39

Identity Object, Class 0x01

Services

Class services

Get Attribute All
Get Attribute Single

Instance services

Get Attribute All
Get Attribute Single
Reset

Class Attributes

# Access

Name

Type

Value Description

1 Get Revision

UINT

0x0001 Revision

1

Instance Attributes

# Access

Name

Type

Value Description

1

Get

Vendor ID

UINT

0x005A

HMS Industrial Networks AB

2

Get

Device type

UINT

0x000C

Communication Adapter

3

Get

Product code

UINT

0x012C

OPC-G11S-ETN drive adapter

Struct of:

-

Version X.YY

USINT XX

Major product version of this
communication module.

4 Get Revision

USINT YY

Minor product version of this
communication module

5 Get Status

WORD -

Status of the device, see table
below.

6 Get Serial

number

UDINT Serial

number

This is the serial number of the
product, assigned when the module
is produced.

7 Get Product

name

SHORT_S
TRING

“OPC-
G11S-
ETN”

The module’s product name.

Status Attribute

Extended Device Status (Bit 4-7)

Bit 0

Owned, shall be set when at least one

connection

is

configured.

Bit 1

Reserved, set to 0.

Bit 2

Configured, is always set to 1.

Bit 3

Reserved, set to 0.

Bit 4-7

See extended device status

Bit 8

Is set for minor recoverable faults.

Bit 9

Is set for minor recoverable faults.

Bit 10

Is set for major recoverable faults.

Bit 11

Is set for major unrecoverable faults.

Bit 12-15 Reserved, set to 0.

0000 = Unknown
0010 = Faulted I/O connection
0011 = No I/O connection established
0100 = Non volatile configuration bad
0110 = Connection in run mode
0111 = Connection in idle mode

Advertising