Data format specification – GE Industrial Solutions AF-300 P11_G11 Ethernet Interface User Manual

Page 39

Advertising
background image

Appendix B - Drive Parameters

33

Data Format Specification

All data within the data field of the communication frame consist of 16 bits binary data.

(MSB)

(LSB)

15 14

13 12

11 10

9 8 7 6 5 4 3 2 1 0

16-bits binary data

(Negative data is treated with two’s complement)

Data Format [1]: Integer Data (Positive): Min. Unit 1

Example) If F15 (Frequency limiter, high limit) = 60 Hz,

60 * 1 = 60 = 003C

H

Data Format [2]: Integer Data (Positive, Negative): Min. Unit 1

Example) If F18 (Bias frequency) = -20 Hz,

-20 * 1 = -20 = FFEC

H

(two’s complement)

Data Format [3]: Decimal Data (Positive): Min. Unit 0.1

Example) If F17 Gain (for frequency setting signal) = 100.0%,

100.0

* 10 = 1000 = 03E8

H

Data Format [4]: Decimal Data (Positive, Negative): Min. Unit 0.1

Example) If H28 (Droop operation) = -5.0Hz,

-5.0 * 10 = -50 = FFCE

H

(two’s complement)

Data Format [5]: Decimal Data (Positive): Min. Unit 0.01

Example) If C05 (Multi-step frequency 1) = 50.25 Hz,

50.25

* 100 = 5025 = 13A1

H

Data Format [6]: Decimal Data (Positive, Negative): Min. Unit 0.01

Example) If M07 (Actual torque value) = -85.38%,

-85.38

* 100 = -8538 = DEA6

H

(two’s complement)

Data Format [7]: Decimal Data (Positive): Min. Unit 0.001

Example) If o05 (Constant I of feedback speed controller) = 0.105s,

0.105 * 1000 = 105 = 0069

H