Configuration messages – GE Industrial Solutions AF-300 P11_G11 Ethernet Interface User Manual
Page 22
EGD
16
Configuration Messages
EGD configuration messages are sent using the HTTP protocol on TCP port 7937, a message request have
the following format:
http://[IP Address]:7937/EGD?Action=[Action]&Type=[Type]&ProducerID=[Producer ID]
The brackets shall be substituted as:
Field Description
IP Address
The modules assigned IP address
Action
GetVersion - Get version information
GetDoc
- Retrieve specified configuration document
Type
Specifies document to be retrieved. Used for GetDoc
ProducerID
Producer ID of module. Used for GetDoc
The following documents can be retrieved:
Document Description
ProducedData Describes
the
produced data exchanges
ConsumedData
Describes the needs for consumed data exchanges
EGDProfile Describes the EGD capabilities
SymbolTable Describes
the
contents of the exchanges
Examples:
http://10.10.12.210:7937/EGD?Action=GetDoc&Type=SymbolTable&ProducerID=10.10.12.210
http://10.10.12.210:7937/EGD?Action=GetVersion