Data format [10]: alarm code, Data format [11]: capacity code – GE Industrial Solutions AF-300 P11_G11 Ethernet Interface User Manual

Page 40

Advertising
background image

Appendix B - Drive Parameters

34

Data Format [8]: Decimal Data (Positive, Negative): Min. Unit 0.001

Example) If value -1.234,

-1.234 * 1000 = -1234 = FB2E

H

(two’s complement)

Data Format [10]: Alarm Code

Code Description

Code Description

0

No alarm

22

Overheat, DB resistor

1

Overcurrent, during acceleration (INV
output)

23

Overload, motor 1

2

Overcurrent, during deceleration (INV
output)

24

Overload, motor 2

3

Overcurrent, during steady state
operation (INV output)

25 Overload,

drive

5 Ground

fault

27 Overspeed

6

Overvoltage, during acceleration

28

PG wire break

7

Over voltage, during deceleration

31

Memory error

8

Overvoltage, during steady state
operation

32 Keypad

error

10

DC undervoltage

33

CPU error

11

Power supply open phase

34

Option comm error

14

Blown DC fuse

35

Option error

16

Output wiring error

36

PL error

17

Overheat, heat sink, inverter

37

Output wiring error

18

Overheat, outside thermal

38

RS485 comm error

19

Overheat, unit inside temp

-

-

Data Format [11]: Capacity Code

Code Capacity

(HP)

Code Capacity (HP) Code

Capacity (HP)

7 0.07

(spare)

2000

20 17500

175

15 0.15

(spare)

2500

25 20000

200

25 0.15

3000

30 25000

250

50 0.15

4000

40 30000

300

100 1 5000

50 35000

350

200 2 6000

60 40000

400

300 3 7500

75 45000

450

500 5 10000

100 50000

500

750 7.5 12500

125 60600

600

1000 10

15000 150 60700 700

1500

15

- - 60800

800

Advertising