Special applications, cont’d – Extron Electronics System 5 IP Series User Guide User Manual

Page 104

Advertising
background image

Special Applications, cont’d

System 5 IP Switchers • Special Applications

6-10

9.

Select User Defined as the type of operation. See the screen shot below.

10.

Select the port via which the command will be sent to the display or source
device.

11.

In the Command space below the port selection menu, enter the command as
an ASCII character string.

Spaces are automatically converted to 20

hex

when the command is sent

out.

All ASCII characters are accepted as-is except the percent symbol (%),
which must be URL encoded. If the percent symbol is not encoded, it is
treated as the start of a hexadecimal command. For example, the
command “POWER%ON” must be entered as “POWER%25ON”, where
% indicates that a hex character follows, and 25 is the hexadecimal
equivalent of the ASCII percent symbol.

12.

Select whether the command should be sent when the button is pressed or
when it is released.

13.

Click OK.

14.

Repeat steps 6 through 13 as needed.

15.

Save (File —> Save) the GC configuration project.

16.

To build the configuration and upload it to the switcher, click the Build menu,
then select one of the build options, and click the Begin button when the
Upload Manager window appears.

Routing Audio to an External Amplifier and a
Volume Controller

Many wireless microphone systems do not provide a volume adjustment. In
installations that include wireless microphones, wired microphones, other audio
sources, and a nonamplifier System 5 IP switcher, an external amplifier and a
volume controller (such as the Extron MVC 121) can be useful integration
accessories. The following diagram shows a sample of this type of system.

Advertising