Configuring the system 5 for switcher slaving, Special applications, cont’d – Extron Electronics System 5 IP Series User Guide User Manual

Page 106

Advertising
background image

Special Applications, cont’d

System 5 IP Switchers • Special Applications

6-12

Configuring the System 5 for switcher slaving

1.

Cable and power on the System 5 IP, the MPS 112, and a host PC. Refer to
“Connecting the System 5 IP and MPS 112” in this chapter.

2.

On the host PC, start the Global Configurator
program, and open the appropriate project file.

3.

Click on the IP Link tab on the left side of the
screen.

4.

Click or double-click on the System 5 IP you wish
to configure to show and expand the menu of
connected devices.

From this point there are two ways to enable switcher
slaving:

5.

Right-click on the MPS 112 shown under the
Audio/Video Configuration

folder.

6.

Select Enable MPS 112, as shown at right.

Or

7.

Click on the Advanced Configuration tab in the
right portion of the screen.

8.

Click the Enable MPS 112 check box in the
Miscellaneous Settings

portion of the screen, as

shown below.

Advertising