Command/response table for special function SIS commands, continued

Command

ASCII Command Response

X?

values

(host to Syst. 5IP)

(switcher to host)

and additional descriptions

Each control module (IRCM, ACM, RCM) has 20 memory blocks reserved for it, no matter how many buttons are
physically present on the module:
• module 1: blocks 26-45
• module 2: blocks 46-65
• module 3: blocks 66-85
• module 4: blocks 86-105
Memory block numbers are sequential from left to right, top row to bottom row, as shown below.

SCREEN POSITION

DOWN

UP

STOP

DVD & VCR CONTROL

PLAY

NEXT/FWD PAUSE

STOP

TUNER

Tx

PREV/REW

ENTER

TITLE

MENU

TV/VCR

DVD

VCR

DVD & VCR CONTROL

PLAY

NEXT/FWD PAUSE

STOP

TUNER

Tx

PREV/REW

ENTER

TITLE

MENU

TV/VCR

DVD

VCR

Button/Switch Memory Block Numbering for Control Modules (IRCMs, ACMs, RCMs)

Memory Block

Numbering Scheme for

Any Type of Module

(Example is for Control Module 1)

Memory Block Numbering Examples

DVD Half

(module 1)

IRCM-DV+ with DIP switch set for addresses 0 and 1

(modules 1 and 2)

RCM-SC with DIP switch set for address 2

(module 3)

VCR Half

(module 2)

26 27 28 29 30

35

30

40

45

31

35

34

33

32

36

40

39

38

37

41

45

44

43

42

31

35

33

32

36

39

29

37

41

45

44

43

42

66

70

68

51

55

53

52

56

59

49

57

61

65

64

63

62

Module 3 has
memory blocks
66 to 85.

Module
1 has
memory
blocks
26 to 45.

Module
2 has
memory
blocks
46 to 65.

Button press repeating

Set the button press repeat rate

24

X?

*

Y?

*45 #

RptRate*

X?

*

Y?

This command sets the switcher
to repeatedly send commands
associated with button

X?

at the

interval specified by

Y?

.

X?

= the number of the memory

block for the button/switch (1 -
127) to set the repeat rate for.
See the diagrams above.

Y?

= the repeat interval

(0 - 65535 ms in 20 ms steps).

Read/display the button press repeat rate

45 #

X?

*

Y?

Clear the button repeat rate

0*0*45 #

RptRate*000*00000

Turn off continuous repeat
mode.