Symbol definitions, Preliminar y, 5 system 5 ip • sis – Extron Electronics System 5 IP Series User Guide User Manual

Page 61: Programming and control

Advertising
background image

5-5

System 5 IP • SIS

Programming and Control

PRELIMINAR

Y

X12

=

Switcher’s name. The name is a text string of up

to 24 characters drawn from the alphabet (A-
Z), digits (0-9), and minus sign/hyphen (-).
No blank or space characters are permitted as
part of a name. No distinction is made
between upper and lower case. The first
character must be a letter. The last character
must not be a minus sign/hyphen.

X13

=

Local date and time format

Set

format (MM/DD/YY-HH:MM:SS).

Example: 11/18/03-10:54:00.

Read

format (day of week, date month year

HH:MM:SS). Example: Tue, 18 Nov 2003
18:19:33.

X14

=

IP address (xxx.xxx.xxx.xxx). Leading zeros in

each of four fields are optional in setting
values, and they are suppressed in returned
values.

X15

=

E-mail domain name, e.g., extron.com

X17

= Time in tens of milliseconds to wait until the first

response character is received via a serial port
before terminating the current command or
operation (Default = 10 = 100 ms,
max. = 32767.)

X18

=

Hardware (MAC) address (xx-xx-xx-xx-xx-xx)

X19

=

Subnet mask (xxx.xxx.xxx.xxx). Leading zeros are

optional in setting values in each of four fields,
and they are suppressed in returned values.

X20

=

Time in tens of milliseconds to wait between

characters being received via a serial port
before terminating the current command or
receive operation
(Default = 2 = 20 ms, max. = 32767)

X21

=

Parameter (#L or #D) to set either the Length of

message to receive or the Delimiter value.
# = byte count (for L) or a single ASCII
character expressed in decimal form (for D).
The parameter is case sensitive; you must use
capital D or capital L.
Byte count # can be from 0 to 32767,
default = 0.
The ASCII decimal # can be from 0 to 00255,
default = the byte count.
Examples:
A 3-byte length = 3L.
A delimiter of ASCII 0A = 10D.
The response from the switcher will include
leading zeros.

X22

= Verbose response mode

0 = clear/none (default for Telnet connections)
1 = verbose mode (the default for RS-232 host
control)
2 = tagged responses for queries
3 = verbose mode and tagged responses for
queries

If you enable tagged responses, all read commands
return the constant string + data. This is much
like what happens when you issue a set command
(for example, command:

Esc

CN

,

response: IPN •

X12

).

X23

=

Priority status for receiving timeouts:

0 = use send data string command parameters
(0 = default)
1 = use configure receive timeout command
parameters

Symbol definitions

=

CR/LF (carriage return/line feed) (hex 0D 0A)

=

Carriage return (no line feed, hex 0D)

(use the pipe character,

|

, instead for Web

browser commands)

=

Space character

|

=

Pipe (vertical bar) character

Esc

=

Escape key (hex 1B)

(use W instead of Esc for Web browsers)

X1

=

Specific port number or relay number (01 – 99

maximum) represented as two ASCII characters
(two bytes)
00 = reserved (all ports)
Relays:
01 = relay 1, 02 = relay 2, 03 = relay 3,
04 = relay 4, 05 = relay 5, 06 = relay 6
Other ports:
01 = rear host (Config/RS-232 port)
03 = slaved switcher
04 = front panel
05 = projector port (Proj Cont)
06 = IR/Serial port A
07 = IR/Serial port B
08 = IR/Serial port C
09 = IR/Serial port D

X2

=

Command data section.

For Web encoding only

: data will be directed to the

specified port and must be encoded (URL encoding)
if it is non-alphanumeric. Change any non-
alphanumeric

character (%, +, |,

, etc.) within

the data section into the corresponding hexadecimal
equivalent, %xx, where xx represents the two-
character hex byte. For example, a space (hex: 20)
would be encoded as %20 (hex: 25 32 30) and a plus
sign (hex: 2B) would be encoded as hex 25 2B.

X3

=

Greenwich Mean Time (GMT) offset value

(-12.00 to +14.00) represents the time difference
in hours and minutes (+/-hh:mm) relative to
Greenwich, England. The plus sign and leading
zero are optional. For example, 5:30 = +05:30.

X5

=

On/off status

0 = off/disable
1 = on/enable

X6

=

Dirty memory status

1 = RAM needs to be saved to flash memory
0 = RAM has been saved to flash (OK to power
off/reset)

X7

=

Bass and treble adjustment range (0 - 10)

(-10 dB to +10 dB in 2 dB steps)
0 = -10 dB
1 = -8 dB
2 = -6 dB

5 = 0 dB (default)

10 = +10 dB

X8

=

Volume adjustment range (0 – 40 steps)

X11

=

Version (typically listed to two decimal places,

e.g., x.xx)