Preliminar y, Programming and control, cont’d – Extron Electronics System 5 IP Series User Guide User Manual

Page 68

Advertising
background image

SIS

Programming and Control, cont’d

System 5 IP • SIS

Programming and Control

5-12

PRELIMINAR

Y

Command/r

esponse table for SIS commands (continued)

Command

ASCII

(T

elnet)

URL Encoded (W

eb)

Response

Additional description

(host to switcher)

(host to switcher)

(switcher to host)

V

iew power sensor status

8S

8S

X213

If the switcher is connected to an Extr

on

Power Sensor that monitors the pr

ojector/

display

, this tells you whether the display is

still power

ed on.

X213

is as follows:

00 = power sensor is connected and is not

sensing pr

ojector power (detector voltage is

low

, signal pin voltage is high).

01 = power sensor is connected and sensing

p

rojector power (detector voltage is high).

02 = sensor is disconnected or sensor is

connected but sensitivity is too high (voltage

is low at both the detector and signal pin).

V

iew power sensor signal pin status

9S

9S

X214

Power sensor signal pin status:

00 = voltage is low

.

01 = voltage is high.

V

iew

all

voltage & temp. status

11

S

11

S

responses fr

om commands 12S

13S

14S

15S

V

iew all voltages (fr

om main and amplifier

power supplies) and the switcher

’s internal

temperatur

e at once.

Example:

11

S

11S

+1

1.2•-1

1.3•+20.0•104

V

iew + main power supply voltage

12S

12S

+

X206

Display the operating voltage of the

switcher

’s + main power supply

.

V

iew - main power supply voltage

13S

13S

X206

Display the operating voltage of the

switcher

’s - main power supply

.

V

iew power amp supply voltage

14S

14S

+

X206

Display the operating voltage of the

amplifier

’s power supply

.

V

iew internal temperatur

e status

15S

15S

X207

Display the internal operating temperatur

e

in degr

ees Fahr

enheit.

Advertising