Preliminar y, Programming and control, cont’d, System 5 ip • sis – Extron Electronics System 5 IP Series User Guide User Manual

Page 72: Programming and control 5-16

Advertising
background image

SIS

Programming and Control, cont’d

System 5 IP • SIS

Programming and Control

5-16

PRELIMINAR

Y

Command/r

esponse table for SIS commands (continued)

Command

ASCII

(T

elnet)

URL Encoded (W

eb)

Response

Additional description

(host to switcher)

(host to switcher)

(switcher to host)

Configur

e an IR/Serial Out port

24

Esc

X215

*

X210

IC

W

X215

%2A

X210

IC

|

Ir

c

X215

*

X210

This command sets IR/Serial Output port

number

X215

(1 = port

A, 2 = port B,

3 = port C, 4 = port D) for either

IR (

X210

= 0) or RS-232 (

X210

= 1) output.

V

iew an IR/Serial port’s config.

Esc

X215

IC

W

X215

IC

|

X210

Example:

Esc

3 IC

W3 IC

|

01

V

iew IR/Serial Output port C’s

configuration, which is RS-232 (01) in this

example.

Ether

net data port configuration and use

Set the timeout period for the LAN (Ethernet) port’s curr

ent connection

24

Esc

0*

X6

9

TC

W0%2A

X6

9

TC

|

Pti 0*

X6

9

Set the time to wait (

X6

9

= waiting time in

tens of ms) to r

eceive the next character

befor

e terminating the Ethernet connection.

The r

esponse includes leading zer

os.

X6

9

= 1-65000 steps at 10 seconds per step,

default = 30 = 300 seconds.

This timeout period applies only when the switcher is connected to a PC via Ethernet. When it is connected to a PC via RS-232,

only the global timeout commands apply

.

V

iew the curr

ent connection timeout period

Esc

0TC

W 0TC

|

X6

9

Set the LAN port’s global timeout period

24

Esc

1*

X6

9

TC

W1%2A

X6

9

TC

|

Pti 1*

X6

9

Set the time to wait (

X6

9

= waiting time in

tens of ms) to r

eceive the next character

befor

e terminating the Ethernet connection.

V

iew the LAN port’s global timeout period

Esc

1TC

W 1TC

|

X6

9

Digital input data port (power sense port, right 3 pins of the pr

ojector/display contr

ol port)

Set I/O mode

24

1*

X40

[

1

%2A

X40

%5B

Iom 1*

X40

X40

= I/O mode

0 = input

8 = power sensor (triggers when the input

pulse starts/stops).

V

iew I/O mode

1[

1

%5B

X40

V

iew I/O state

1]

1 %5D

X43

X43

= I/O state

0 = of

f

1 = on

An input voltage of less than 0.6 VDC is consider

ed as logic low

, and an input voltage of gr

eater than 0.7 VDC is considered to

be logic high. These thr

esholds ar

e not

adjustable.